Young Ultrasonic Anemometer Heated Model 85004 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Young Ultrasonic Anemometer Heated Model 85004. Young Ultrasonic Anemometer Heated Model 85004 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
METEOROLOGICAL INSTRUMENTS
INSTRUCTIONS
R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA
TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com
PN: 85004-90
REV: G110410
ULTRASONIC ANEMOMETER (HEATED)
MODEL 85004
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTSINSTRUCTIONSR.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USATEL: (231) 946-3980 FAX: (23

Strona 2 - OPERATING INSTRUCTIONS

Page 785004-90 Voltage Output: Disabled Sample Count: Set to 0 if polling frequently. Set to highest anticipated wind speed (m/s) up to 3

Strona 3

Page 885004-90APPENDIX A: WIRING CONNECTIONS

Strona 4 - MODEL 85004

Page 985004-90APPENDIX A: WIRING CONNECTIONS

Strona 5 - 5.0 OPERATION

Page 1085004-90APPENDIX A: WIRING CONNECTIONS

Strona 6

Page 1185004-90APPENDIX A: WIRING CONNECTIONS

Strona 7 - PARAMETERS

Page 1285004-90APPENDIX A: WIRING CONNECTIONS

Strona 8 -  SET09nn  Damping factor

Page 1385004-90TOP VIEWNORTH347 [13.7]FRONT VIEWORIENTATION RING0°90°180°270°(WIND SPEED, WIND DIRECTION)(U-V)+U(WIND FROM EAST)+V(WIND FROM NORTH)EX

Strona 9 - 7.0 EXAMPLE SETTINGS

ContentsSECTION DESCRIPTION PAGE1.0 SPECIFICATIONS 12.0 INTRODUCTION 13.0

Strona 11 - 85004-90

Page 185004-90MODEL 85004ULTRASONIC ANEMOMETERHEATED1.0 SPECIFICATIONSWIND SPEEDRange: 0-70 m/s (156 mph)Resolution: 0.1 m/sAccuracy: 0 to 30 m/s

Strona 12

Page 285004-90 IMPORTANT: The Wind Tracker input option must be set to "INP 09". See the Wind Tracker manual for set-ting this option.3.2

Strona 13 - Page 10

Page 385004-905.3.2 ASCIIASCII output provides continuous wind measurement data in text format. Between each measurement cycle, the sensor goes into

Strona 14 - Page 11

Page 485004-90 aC! a00102<CR><LF> aC1! a00102<CR><LF> aCC! a00102<CR><LF> aCC1! a00102<CR><LF>

Strona 15 - Page 12

Page 585004-90parameters are automatically changed. This may change the baud rate from its current setting. See section 6.4.2 for details on which pa

Strona 16 - CARTESIAN

Page 685004-906.4.9 SET09nn SET DAMPING FACTORWind measurement outputs are damped using the following formula: Sdamped = [(d-1) * Sdamped + Ssamp

Komentarze do niniejszej Instrukcji

Brak uwag